> Services > Dell iDRAC > CPU Status (Dell iDRAC) Service

CPU Status (Dell iDRAC) Service

The CPU Status (Dell iDRAC) service monitors the health of a physical CPU on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type

SNMP

Instances on a Device

100

Supported Systems/Applications

Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC)

Device Class for CPU (SNMP)

Servers - Management Interface

Monitored By

Windows Agent

Scan Interval

15 minutes

SNMP Value

Enter or select the name of the CPU to monitor in the format ProcessorFQDD (Fully Qualified Device Descriptor) of each processor device. For a list of CPUs, query the device with the .1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 SNMP OID.

Status Detail

Object Descriptors

Numerical OID

Description

Name

$DeviceBrandName

1.3.6.1.4.1.674.10892.5.4.1100.30.1.23

Indicates the brand name and model of the processor device.

Status

$Status

1.3.6.1.4.1.674.10892.5.4.1100.30.1.5

Indicates the current status of the processor device mapped as:

1 - other,

2 - unknown,

3 - ok,

4 - nonCritical,

5 - critical, and,

6 - nonRecoverable.