> Services > Dell iDRAC > Chassis Intrusion (Dell iDRAC) Service

Chassis Intrusion (Dell iDRAC) Service

The Chassis Intrusion (Dell iDRAC) service monitors the chassis security feature that detects if a chassis component is removed or replaced from a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type

SNMP

Instances on a Device

100

Supported Systems/Applications

Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC)

Device Class for CPU (SNMP)

Servers - Management Interface

Monitored By

Windows Agent

Scan Interval

15 minutes

SNMP Index

Enter or select the name of the SNMP Index to be used by this service.

Status Detail

Object Descriptors

Numerical OID

Description

Status

$Status

1.3.6.1.4.1.674.10892.5.4.300.70.1.5

Indicates the current status of the chassis intrusion sensor mapped as:

1 - other,

2 - unknown,

3 - ok,

4 - nonCritical,

5 - critical, and,

6 - nonRecoverable.

Reading

$Reading

1.3.6.1.4.1.674.10892.5.4.300.70.1.6

Indicates where or not the chassis intrusion sensor is currently being read mapped as:

1 - chassisNotBreached,

2 - chassisBreached,

3 - chassisBreachedPrior, and,

4 - chassisBreachSensorFailure.

Type

$Type

1.3.6.1.4.1.674.10892.5.4.300.70.1.7

Indicates the type of the intrusion sensor used for chassis security mapped as:

1 - chassisBreachDetectionWhenPowerON, and,

2 - chassisBreachDetectionWhenPowerOFF.

Settings

$Setting

1.3.6.1.4.1.674.10892.5.4.300.70.1.4

Indicates the current state settings of the intrusion sensor mapped as:

1 - unknown,

2 - enabled,

4 - notReady, and

6 - enabledAndNotReady.