> Services > Dell iDRAC > Physical Drive (Dell iDRAC) Service

Physical Drive (Dell iDRAC) Service

The Physical Drive (Dell iDRAC) service monitors various elements related to the status of a physical drive in a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type

SNMP

Instances on a Device

100

Supported Systems/Applications

Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC)

Device Class for CPU (SNMP)

Servers - Management Interface

Monitored By

Windows Agent

Scan Interval

15 minutes

SNMP Index

Enter or select the name of the drive to monitor. For a list of drives, query the device with the .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54 SNMP OID.

Status Detail

Object Descriptors

Numerical OID

Description

Disk Name

$Name

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2

Indicates the physical name of the disk as represented in Storage Management.

State

$State

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4

The current state of the physical disk being monitored mapped as:

Normal:

Online (3): RAID configuration has been assigned to the physical disk.

Warning:

Ready (2): Physical disk is available for use but no RAID configuration has been assigned.

Failure:

Unknown (1): Cannot determine current state.

 

Foreign (4): Physical disk has been moved from another controller and contains all or some portion of a virtual disk.

 

Offline (5): Physical disk is not available to the RAID controller.

 

Blocked (6): Physical disk is currently blocked by controller.

 

Failed (7): Physical disk is not operational.

 

Non-RAID (8): Physical disk is not a RAID capable disk.

 

Removed (9): Physical disk has been removed.

Serial Number

$SerialNo

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7

Indicates the physical disk's unique identification number provided by the manufacturer.

Disk Capacity

$DiskCapaity

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11

Indicates the size of the physical disk (in megabytes).

Used Space (GB)

$UsedSpace

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17

Indicates the amount of used space (in gigabytes) on the physical disk.

Used Space Percentage (%)

n/a

n/a

Calculated using the formula:

$UsedSpace $DiskCapaity / 100.0 *

Free Space (MB)

$FreeSpace

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19

Indicates the amount of space (in megabytes) currently available on the physical disk.

Spare State

$SpareState

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22

Indicates the status of the array disk as a spare mapped as:

  • 1: notASpare - Physical disk is not a spare.
  • 2: dedicatedHotSpare - Physical disk is a dedicated hot spare.
  • 3: globalHotSpare - Physical disk is a global hot spare.

Display Name

$DisplayName

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55

Indicates the physical disk's friendly FQDD as represented in Storage Management.

Smart Alert

$SmartAlert

1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31

Indicates whether or not the physical disk has received a predictive failure alert.