> Services > Dell iDRAC > System Battery Status (Dell iDRAC) Service

System Battery Status (Dell iDRAC) Service

The System Battery Status (Dell iDRAC) service monitors the status of a system board CMOS battery on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type

SNMP

Instances on a Device

100

Supported Systems/Applications

Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC)

Device Class for CPU (SNMP)

Servers - Management Interface

Monitored By

Windows Agent

Scan Interval

15 minutes

SNMP Value

Enter or select the name of the battery to Applied new templates.. For a list of batteries, query the device with the .1.3.6.1.4.1.674.10892.5.4.600.50.1.7 SNMP OID.

Status Detail

Object Descriptors

Numerical OID

Description

Chassis Index

$ChassisIndex

1.3.6.1.4.1.674.10892.5.4.600.50.1.1

Indicates the index of the system chassis that contains the battery as an integer value between 1 and 128.

Status

$Status

1.3.6.1.4.1.674.10892.5.4.600.50.1.5

Indicates the current status of the battery mapped as:

1 - other,

2 - unknown,

3 - ok,

4 - nonCritical,

5 - critical, and,

6 - nonRecoverable.