> Services > Dell iDRAC > Temperature Probe (Dell iDRAC) Service

Temperature Probe (Dell iDRAC) Service

The Temperature Probe (Dell iDRAC) service monitors the status of a temperature sensor on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service Type

SNMP

Instances on a Device

100

Supported Systems/Applications

Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC)

Device Class for CPU (SNMP)

Servers - Management Interface

Monitored By

Windows Agent

Scan Interval

5 minutes

SNMP Value

Enter or select the name of the temperature sensor to monitor.

Status Detail

Object Descriptors

Numerical OID

Description

Location Name

$LocationName

1.3.6.1.4.1.674.10892.5.4.700.20.1.8

Indicates the location name of the temperature probe.

Settings

$Setting

1.3.6.1.4.1.674.10892.5.4.700.20.1.4

Indicates the state settings of the temperature probe mapped as:

1 - unknown

2 - enabled

4 - notReady

6 - enabledAndNotReady

Status

$Status

1.3.6.1.4.1.674.10892.5.4.700.20.1.5

Indicates the current status of the temperature sensor mapped as:

1 - other

2 - unknown

3 - ok

4 - nonCriticalUpper

5 - criticalUpper

6 - nonRecoverableUpper

7 - nonCriticalLower

8 - criticalLower

9 - nonRecoverableLower

10 - failed