> Services > EqualLogic > Temperature Status (EqualLogic) Service

Temperature Status (EqualLogic) Service

The Temperature Status (EqualLogic) service monitors the temperature of a Model PS6100 Dell EqualLogic SAN running v6.0.2 firmware.

Service Type

SNMP

Instances on a Device

1

Supported Systems/Applications

Model PS6100 Dell EqualLogic SAN running v6.0.2 firmware

Device Class

Server - Generic, Server - Windows

Monitored By

Windows Agent

Scan Interval

5 minutes

Temperature Sensor Enter the name of the temperature sensor to monitor. For a list of temperature sensors, query the SAN with the .1.3.6.1.4.1.12740.2.1.6.1.2 SNMP OID.

Object Descriptors

Numerical OID

$Temperature 1.3.6.1.4.1.12740.2.1.6.1.3
$SensorState 1.3.6.1.4.1.12740.2.1.6.1.4

Status Detail

Description

Temperature (°C)

The current temperature reading.

Sensor State

The temperature sensor status is mapped as:

  • Normal = 1
  • Warning = 2, 0
  • Failed = 3

Sensor State Description

Description of the status of the temperature sensor:

  • 0 = Unknown
  • 1 = Normal
  • 2 = Warning
  • 3 = Critical