> Services > Fan Status > Fan Status (HP) Service

Fan Status (HP) Service

The Fan Status (HP) service monitors the condition of the system and CPU fans for Compaq/HP ProLiant servers.

Special Note

This service operates in conjunction with the vendor-supplied hardware agent and requires SNMP to be configured so that it is accessible from both the MSP N-central Agent and the MSP N-central Probe.

The following are the requirements in order to associate this service with a device:

  • The device must undergo discovery using a Probe-based asset scan.
  • You need to enable SNMP enabled on the device on the Properties tab of the device.
  • Once you enable SNMP for the device, you need to configure a community string. The default community string is public.

Service Type

SNMP

Instances on a Device

1

Supported Systems/Applications

HP Proliant Servers running HP Insight Manager agents

Device Class

Server - Generic, Workstation - Generic, Other, Printer, Scanner/Camera, Switch/Router, and Server - Windows

Monitored By

Windows Probe

Scan Interval

15 minutes

OID/Calculation

Metric Name

OID/Calculation

Description

System Fan (HP)

.1.3.6.1.4.1.232.6.2.6.4

The status of the fans in the system is mapped as:

  • Normal: 1, 2
  • Warning: 3
  • Failed: 4

where the values are:

  • 1: Other, fan status detection is not supported by this system or driver.
  • 2: OK, all fans are operating properly.
  • 3: Degraded, a non-required fan is not operating properly.
  • 4: Failed, a required fan is not operating properly.

CPU Fan (HP)

.1.3.6.1.4.1.232.6.2.6.5

The status of the processor fans in the system is mapped as:

  • Normal: 1, 2
  • Warning: 3
  • Failed: 4

where the values are:

  • 1: Other, fan status detection is not supported by this system or driver.
  • 2: OK, all fans are operating properly.
  • 3: Degraded, a non-required fan is not operating properly.
  • 4: Failed, a required fan is not operating properly.