> Services > NetApp > Power Supply (NetApp)

Power Supply (NetApp)

The Power Supply (NetApp) service monitors the status of a power supply in a NetApp device.

For more information, see www.netapp.com/us/.

Manufacturer Information

Service Type

SNMP

Discovery OID

Index 0

Supported Systems/Application

NetApp Device with SNMP enabled

MSP N-central Information

Known Limitations

N/A

Max. Instances Per Device

1

Supported Device Class

Storage

Notification Profile

N/A

Monitored By

Probe

Troubleshooting

Issue Recommendation
Misconfigured Check to see if you have the correct credential on the device.

Metrics 1

OID 1.3.6.1.4.1.789.1.2.4.4

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Failed Power Supplies N/A N/A 0: No (Normal)
1: Yes (Failed)

Metrics 2

OID 1.3.6.1.4.1.789.1.2.4.5

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Message N/A N/A Off