> Services > Power Supply > Power Supply (Intel) Service

Power Supply (Intel) Service

The Power Supply (Intel) service monitors the overall condition of the specified power supply on a server with an Intel Motherboard.

Special Note

This service operates in conjunction with the vendor-supplied hardware agent and requires SNMP to be configured so that it is accessible from both the MSP N-central Agent and the MSP N-central Probe.

The following are the requirements in order to associate this service with a device:

  • The device must undergo discovery using a Probe-based asset scan.
  • You need to enable SNMP enabled on the device on the Properties tab of the device.
  • Once you enable SNMP for the device, you need to configure a community string. The default community string is public.

Service Type

SNMP

Instances on a Device

2

Supported Systems/Applications

Devices using an Intel motherboard, with the Intel SMS software installed.

Device Class

Server - Generic, Server - Windows

Monitored By

Windows Probes

Scan Interval

5 minutes
Power Supply Name The name of the power supply to be monitored. You can obtain the names of power supplies available for monitoring by querying the device with the 1.3.6.1.4.1.343.2.10.3.5.400.20.1.3 SNMP OID.

OID/Calculation

Metric Name

OID/Calculation

Description

Power Supply Status 1.3.6.1.4.1.343.2.10.3.5.400.20.1.5

The status of the power supply is mapped as:

  • Normal: 3
  • Warning: 1, 2, 4, 5
  • Failed: 6

Where:

  • 1: Other
  • 2: Unknown
  • 3: OK
  • 4: Non-critical
  • 5: Critical
  • 6: Non-recoverable
Power Supply Status Description 1.3.6.1.4.1.343.2.10.3.5.400.20.1.5

Describes the status of the power supply as one of:

  • Other
  • Unknown
  • OK
  • Non-critical
  • Critical
  • Non-recoverable